The Collier Report of U.S. Government Contracting

Old School Reporting Using Modern Technology

Russelectric Inc

  • Contact Person: John Kirby
  • Contact Phone: 781-749-6000
  • Contact Email: JFKIRBY@RUSSELECTRIC.COM
  • Business Structure:
  • Corporate Entity (Not Tax Exempt)
  • Business Type:
  • For Profit Organization
  • Veteran Owned Business
  • Industries Served: Switchgear and Switchboard Apparatus Manufacturing
  • Product Areas: FOOTWEAR, MEN'S, FOOTWEAR, WOMEN'S

Sampling of Federal Government Funding Actions/Set Asides

In order by amount of set aside monies.

  • $5,145 - Monday the 3rd of December 2012
    US Customs And Border Protection
    AVIATION, MARITIME&BORDER TECHNOLOGIES CONTRACTING DIVISION
    OTHER FUNCTIONS - PREVENTIVE MAINTENANCE ON AUTOMATIC ELECTRIC TRANSFER SWITCHES INSTALLED IN CASE OF AN EMERGENCY POWER OUTAGES AT THE AMOC FACILITY AT MARCH AIR RESERVE BASE IN CA.
  • $20,666 - Friday the 10th of July 2015
    Veterans Affairs Department
    243-NETWORK CONTRACTING OFFICE 03
    CONTRACTOR SHALL PROVIDE AND FURNISH ALL SUPERVISION, ENGINEERING, MATERIALS, LABOR AND TOOLS NECESSARY TO MODIFY THE RUSSELECTRIC SWITCHGEARS IN THE GENERATOR ROOM LOCATED IN THE GROUND FLOOR NORTH WING AT THE MANHATTAN VA MEDICAL CENTER AT 423 EAST 23RD ST., NEW YORK, NY 10010. THE SCOPE OF WORK INCLUDES, BUT NOT LIMITED TO 1. PROVIDE A 2-POSITION, DOOR MOUNTED SELECTOR SWITCH MARKED GEN 1 2 3 GEN 4 FOR INSTALLATION ON THE MASTER CONTROL DOOR. 2. PROVIDE THE MODIFICATIONS TO THE ENGINE START CIRCUITS TO START THE EXISTING ENGINES UPON RECEIPT OF AN ENGINE START SIGNAL WHEN THE ABOVE SELECTOR SWITCH IS IN THE GEN 1 2 3 POSITION. WHEN THE SELECTOR SWITCH IS IN THE GEN 4 POSITION, PROVIDE A CONTACT TO CLOSE, WIRED TO A TERMINAL STRIP, FOR CUSTOMER USE. THE EXISTING ENGINE WOULD NOT START WHEN THE SWITCH IS IN THE GEN 4 POSITION. 3. PROVIDE THE MODIFICATIONS REQUIRED TO BYPASS ALL LOAD SHED/BLOCK TRANSFER CONTROLS WHEN THE ABOVE SELECTOR SWITCH IS IN THE GEN 4 POSITION. 4. PROVIDE THE REVISED DRAWINGS INCORPORATING THE PREVIOUSLY DESCRIBED MODIFICATIONS.
  • $13,908 - Wednesday the 4th of April 2012
    Veterans Affairs Department
    546-MIAMI
    ELECTRICAL SUB-STATION EMERGENCY REPAIRS
  • $138,040 - Friday the 13th of January 2012
    Public Buildings Service
    WPHBA - CAPITAL CONSTRUCTION BRANCH
    CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT AND SUPERVISION TO PROVIDE AN ADDITIONAL UPS SYSTEM AND SWITCHGEAR TO THE HST MAIN STATE BUILDING FOR THE PHASE 2 PORTION IN THE 2ND FLOOR ROOF EMERGENCY POWER UPGRADES PROJECT ACCORDING TO THE SCOPE OF WORK DATED AUGUST 8, 2011. THE EQUIPMENT IS TO BE PROVIDED BY RUSSELECTRIC INC. QUOTE # 157151B DATED JUNE 17, 2011. THE EQUIPMENT THAT SHALL BE PROVIDED INCLUDES: 1 - RUSSELECTRIC 480V CRITICAL INPUT SWITCHGEAR (CISB) ITEM 1 CISB INPUT SWITCHGEAR LOAD SIDE MAIN CIRCUIT BREAKER CUBICLE WILL CONSIST OF THE FOLLOWING: 1 - METAL ENCLOSED CUBICLE 1 - 1600 AMP ELECTRICALLY OPERATED LOAD SIDE MAIN CIRCUIT BREAKER, GE WAVE PRO TYPE RATED AT 200KAIC AT 480 VOLTS 1 - BUSSED CRADLE FOR FUTURE 1600 AMP BREAKER ELEMENT 1 - POWER METER SQ-D PM870 1 - SET OF 3 PHASE 2,000 AMP LOAD BUSS WITH SEPARATE 1500 AMP GROUND BUS 1 - SET OF COMPRESSION TYPE LUGS 1 - SET OF TRACK FOR OVERHEAD LIFTIN 1 - SET OF CONTROL WIRING, FUSES, FUSE BLOCKS, TERMINALS, NAMEPLATES, ETC. LOAD SIDE DISTRIBUTION CIRCUIT BREAKER SECTION 2 - METAL ENCLOSED CUBICLE 1 - 800 AMP ELECTRICALLY OPERATED LOAD SIDE FEEDER CIRCUIT BREAKER, GE WAVE PRO TYPE RATED AT 200KAIC AT 480 VOLTS 5 - 1600 AMP FRAME ELECTRICALLY OPERATED LOAD SIDE FEEDER CIRCUIT BREAKERS GE WAVE PRO TYPE RATED 200KAIC AT 480 VOLTS 1 - SET OF 3 PHASE 2,000 AMP LOAD BUS WITH SEPARATE 1,500 AMP GORUND BUS 6 - SETS COMPRESSION TYPE LUGS FOR INCOMING FEEDER BREAKER CABLE CONNECTIONS 2 - SETS OF TRACK OVERHEAD LIFTING DEVICE 2 - SETS OF CONTROL WIRING, FUSES, FUSE BLOCKS, TERMINALS, NAMEPLATES, ETC. ITEM 2 ATS-B LOAD SIDE BUSSING ALL NECESSARY BUS SPLICE PLATES/HARDWARE AND FIELD SERVICE TO FIELD INSTALL THE LOAD SIDE OF THE EXISTING ATSB INTO THE NEW ATS-B LOAD SIDE MAIN BREAKER INCLUDED IN ITEM 1 THE PERIOD OF PERFORMANCE HAS BEEN EXTENDED AN ADDITIONAL 60 DAYS OR NO LATER THAN FEBRUARY 29, 2012. YOU MUST SUBMIT YOUR ORIGINAL INVOICE ELECTRONICALLY AT WWW.FINANCE.GSA.GOV WITH ONE (1) COPY TO THE ADDRESS IN BLOCK 6, ATTN: LAURA SPAIN TO ENSURE PROMPT AND TIMELY PAYMENT OF YOUR INVOICES. PLEASE NOTE THAT FAXED OR EMAILED INVOICES ARE NO LONGER ACCEPTABLE. YOU MUST SUBMIT YOUR INVOICE ELECTRONICALLY.
  • $10,511 - Thursday the 12th of July 2012
    Department Of Navy
    NAVAL MEDICAL CENTER PORTSMOUTH VA
    INSTALL MODIFICATION

© Copyright 2019
The Collier Report
published by 1918 Media LLC.
Information displayed in this dossier has been provided through available open source or public sources. No reliance should be made by readers or Collier Report subscribers. Funding actions are complicated and do not always represent dollar-for-dollar payments to vendors nor do they represent payments in certain instances. Requests for the modification of displayed information may be made to help.desk@1918.media.