United Solutions And Services Llc
- View government funding actions
- Hockessin, DE 197071142
- Phone:
- Corporate URL: www.us2llc.com
- Estimated Number of Employees: 32
- Estimated Annual Receipts: $7,000,000
- Business Start Date: 2004
- Contact Person: Shane Muncy
- Contact Phone: 703-686-2284
- Contact Email: smuncy@capefoxss.com
- Business Structure:
- Corporate Entity (Not Tax Exempt)
- Business Type:
- Alaskan Native Corporation Owned Firm
- For Profit Organization
- Limited Liability f
- Industries Served: Gift, Novelty, and Souvenir Stores, Data Processing, Hosting, and Related Services, Custom Computer Programming Services, Computer Systems Design Services, Computer Facilities Management Services, Other Computer Related Services, Administrative Management and General Management Consulting Services, Human Resources Consulting Services, Marketing Consulting Services, Other Management Consulting Services, Environmental Consulting Services, Other Scientific and Technical Consulting Services, Research and Development in the Social Sciences and Humanities, All Other Professional, Scientific, and Technical Services, Office Administrative Services, Other Individual and Family Services
- Product Areas: SERVICES (BASIC), R&D- DEFENSE OTHER: SERVICES (BASIC RESEARCH), R&D- DEFENSE OTHER: SERVICES (MANAGEMENT/SUPPORT), SERVICES (MANAGEMENT/SUPPORT)
Sampling of Federal Government Funding Actions/Set Asides
In order by amount of set aside monies.
- $97,111 - Friday the 2nd of March 2012
Department Of Army
W076 ENDIST FT WORTH
CONTRACT FOR C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TEXAS. REFERENCE NO. R00017 MG036 ADDITIONAL OUTLETS MG037 SAW CUT 15 INCH APRON MG039 REVISE HANGAR DOOR SOFFIT A. SCOPE OF WORK MG036 ADDITIONAL OUTLETS 1. PROVIDE AND INSTALL ONE NEW 120VAC, 20A DUPLEX OUTLET ON THE CENTER OF THE EAST WALL IN TOOLS ROOM 112. 2. PROVIDE AND INSTALL ONE NEW 120VAC, 20A DUPLEX OUTLET ON THE CENTER OF THE WEST WALL IN TOOLS ROOM 112. 3. PROVIDE AND INSTALL ONE NEW (1V/2D) VOICE/NIPR DATA OUTLET ON THE NORTH WALL AND LOCATE TO THE EAST OF THE PERSONNEL DOOR, ADJACENT TO THE EXISTING 120VAC RECEPTACLE IN TOOLS ROOM 112. MG037 SAW CUT 15 INCH APRON SAW CUT 15 INCH APRON JOINTS AND SEAL THEM IN ACCORDANCE WITH THE ATTACHED MG037, SKETCHES 1-2 OF 2. MG039 REVISE HANGAR DOOR SOFFIT PROVIDE AND INSTALL THE HANGAR DOOR SOFFIT IN ACCORDANCE WITH THE RESPONSE TO RFI #122. - $86,576 - Monday the 31st of October 2011
Department Of Army
W076 ENDIST FT WORTH
TREASURY ACCOUNT SYMBOLO: 57-2009-3300 CONTRACT FOR C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TEXAS. REFERENCE NO. R00009 MG020 MORE MANDATORY CHANGES MG021 ADD DOWELS MG022 ADD GRATING CLIPS - $81,833 - Tuesday the 21st of February 2012
Department Of Army
W076 ENDIST FT WORTH
CONTRACT FOR C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TEXAS. REFERENCE NO. R00015MG034ADDITIONAL CONCRETE SAW CUTTING A. SCOPE OF WORK MG034 ADDITIONAL CONCRETE SAW CUTTING SAW CUT AND SEAL THE CONCRETE JOINTS IN ACCORDANCE TO THE ATTACHED MG034 SKETCH 1 OF 1. - $80,602 - Wednesday the 15th of February 2012
Department Of Army
W076 ENDIST FT WORTH
CONTRACT FOR C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TEXAS. REFERENCE NO. R00014 MG030ADDITIONAL SIGNAGE. A. SCOPE OF WORK MG030 ADDITIONAL SIGNAGE PROVIDE AND INSTALL THE ADDITIONAL STRIPING AND SIGNAGE IN ACCORDANCE WITH BELOW INFORMATION AND THE ATTACHED INFORMATION. 1. INTERIOR HANGAR 4230 6" WIDE YELLOW RETRO-REFLECTIVE AIRCRAFT TOW CENTERLINE, FLOOR STRIPING IN THE EAST AND WEST BAYS [PHOTO 1]. 2. EXTERIOR HANGAR 4230 6" WIDE YELLOW RETRO-REFLECTIVE AIRCRAFT TOW CENTERLINE APRON PAVEMENT STRIPING FROM HANGAR 4225 TO HANGAR 4230 [PHOTO 2]. 3. ONE (1) EACH EXTERIOR HANGAR 6" WIDE RED RETRO-REFLECTIVE RESTRICTED AREA BOUNDARY MARKING TO EXTEND 50' SOUTH OF THE HANGAR LARGE ROLLING DOORS [PHOTO 1]. 4. FOUR (4) EACH 4" WIDE X 20' LONG WHITE RETRO-REFLECTIVE ECP LOCATIONS [PHOTO 1]. 5. FOUR (4) EACH 6' LONG X 30" HIGH PAINTED ENTRY CONTROL POINT SIGNS [PHOTO 2]. 6. NINE (9) EACH 6' LONG X 30" HIGH RESTRICTED AREA SIGNS. [PHOTO 4] 7. NINE (9) EACH 5'LONG X 4' HIGH WARNING SIGNS. [PHOTO 3] 8. TWO (2) EACH LARGE ROLLING DOOR CLEAR ZONE AREA MARKINGS DESIGNATED BY 6" WIDE YELLOW AND BLACK DIAGONAL STRIPING 10' INSIDE AND 10' OUTSIDE OF THE HANGAR. [PHOTO 5] 9. TWENTY SIX (26) EACH 20" X 14" PAINTED DANGER SIGNS ADJACENT TO THE CLEAR ZONES. [PHOTOS 5&7]. 10. EIGHT (8) EACH 18" X 15" PAINTED ALUMINUM SIGNS MECHANICALLY FASTENED TO PERSONNEL DOORS INDICATING WARNING - RESTRICTED AREA ENTRY [PHOTO 10]. 11. EIGHT (8) EACH 18" X 4" PAINTED ALUMINUM SIGN MECHANICALLY FASTENED TO PERSONNEL DOORS INDICATING RESTRICTED AREA WHEN AIRCRAFT PRESENT [PHOTO 10]. 12. TWO (2) EACH DANGER SIGNS INDICATING "ONLY QUALIFIED PERSONNEL AUTHORIZED BY THEIR SQUADRON COMMANDER MAY OPERATE HANGAR DOORS" [PHOTO 8&9]. 13. FOUR (4) EACH DANGER SIGNS INDICATING "DOORS SHALL BE FULLY CLOSED OR PARKED WITH NOT LESS THAN A 10 FEET OPENING", ONE INSIDE AND ONE OUTSIDE BOTH CENTER DOORS [PHOTOS 6&8]. 14. SIX (6) EACH CONTROL PANEL MARKING DIRECTIONAL ARROWS, LUMINESCENT OR REFLECTIVE DIRECTIONAL, PLACED ADJACENT TO EACH OPEN AND CLOSE DOOR CONTROL SWITCH AND ALSO ON THE EXTERIOR OF THE TWO CENTER DOORS TO INDICATE DIRECTION OF DOOR TRAVEL. [PHOTO 5&8] 15. TWO (2) EACH ~10"WIDE BY 14" HIGH BY 1/4" THICK CLEAR PLEXIGLAS LETTER HOLDER MECHANICALLY FASTENED TO DOOR CAPABLE OF DISPLAYING AN 8.5" X 11" LETTER FROM THE UNIT COMMANDER CONTAINING A LIST OF QUALIFIED PERSONNEL THAT HAVE HAD ANNUAL TRAINING ON OPERATION OF THE DOORS; AND WHO ARE AUTHORIZED TO OPERATE THE HANGAR DOORS. [PHOTO 9]. - $73,709 - Friday the 16th of December 2011
Department Of Army
W0L6 USA DEP LETTERKENY
ADD FUNDING - $71,291 - Monday the 6th of February 2012
Department Of Army
W076 ENDIST FT WORTH
CONTRACT FOR C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TEXAS. REFERENCE NO. R00013 MG031 ADD HVAC SHUTDOWN MG033ADDITIONAL BRACING FOR TRANSLUCENT PANEL A. SCOPE OF WORK MG031 ADD HVAC SHUTDOWN PROVIDE AND INSTALL TWO LIMIT SWITCHES AND ALL THE ASSOCIATED CONDUIT AND WIRING. THE MAU CONTROLS PROGRAM WILL ALSO HAVE TO BE UPDATED TO INCORPORATE THE LIMIT SWITCH INPUTS TO DETERMINE IF THE HANGAR DOORS ARE OPEN OR CLOSED IN ORDER TO SHUTDOWN THE MAUS WHEN THE DOORS ARE OPEN DURING THE NORMAL RUN MODE. MG033 ADDITIONAL BRACING FOR TRANSLUCENT PANEL PROVIDE AND INSTALL ADDITIONAL FRAMING TO ACCOMMODATE THE ADDITIONAL 1,656 SQUARE FEET OF HANGAR DOOR TRANSLUCENT PANELS IN ACCORDANCE WITH RFI #75. - $382,000 - Tuesday the 27th of March 2012
Department Of Army
W076 ENDIST FT WORTH
CONTRACT FOR C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TEXAS. REFERENCE NO. R00018 MG038 REPLACE TUG ROUTE A. SCOPE OF WORK MG038 REPLACE TUG ROUTE REMOVE AND REPLACE THE IDENTIFIED TUG ROUTE CONCRETE PANELS IN ACCORDANCE WITH THE ATTACHED MG038 SKETCHES 1-3 OF 3. - $37,185 - Friday the 24th of February 2012
Department Of Army
W076 ENDIST FT WORTH
C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TX. REFERENCE NO. R00016 MG035 REVISED HANGAR FLOOR REPAIR A. SCOPE OF WORK MG035 REVISED HANGAR FLOOR REPAIR REPAIR THE FOUR HANGAR FLOOR PANELS IN THE EAST HANGAR BAY AS SHOWN ON MG035 SKETCH 1 OF 1. THESE CONCRETE PANELS SHALL BE SHAVED DOWN A MINIMUM OF A 1/4 INCH OR UNTIL SOLID CONCRETE IS REACHED. THEN, THE AREA WILL BE BUILT BACK UP WITH ARDEX K 301 THAT WILL BE PAINTED WITH A WATER BASED PAINT TO MATCH EXISTING FLOOR COLOR. ALL WORK SHALL BE WARRANTED FOR 1-YEAR. THIS SCOPE OF WORK IS A CORRECTION/REVISION TO P00012, WHICH INCLUDED SANDING ONLY 1/16 OF AN INCH OFF OF THESE FOUR IDENTIFIED CONCRETE PANELS. - $27,339 - Wednesday the 18th of January 2012
Department Of Army
W0L6 USA DEP LETTERKENY
LABORERS - $175,880 - Friday the 20th of January 2012
Department Of Army
W076 ENDIST FT WORTH
CONTRACT FOR C130J-MULTI PURPOSE MAINTENANCE HANGER, PN: FNWZ 053007 AT DYESS AIR FORCE BASE, TEXAS. REFERENCE NO. R00011 MG025 EXTEND DRAFT CURTAINS MG027 REPAIR HANGAR FLOOR SLAB MG028 ADD EXTERNAL NOTIFICATION HORNS MG029 REVISE STORM INLET&400 HZ CABLE A. SCOPE OF WORK MG025 EXTEND DRAFT CURTAINS EXTEND THE EXISTING DRAFT CURTAINS FROM COLUMN LINE 9 TO COLUMN LINE 10 IN ACCORDANCE WITH THE RESPONSE TO RFI #149. THE CURTAIN EXTENSIONS SHALL BE MOUNTED TO THE FLANGES ON THE ROOF MEMBERS ALONG N.5 SIMILAR TO DETAIL 4/MSB209 IN ORDER TO MISS DIAGONAL BRACING. MG027 REPAIR HANGAR FLOOR SLAB REPAIR THE FOUR IDENTIFIED SECTIONS OF HANGAR CONCRETE AS SHOWN ON MG027 SKETCH 1 OF 1 THAT ARE DELAMINATING DUE TO A BOMB THREAT ON SEPTEMBER 9, 2011 CAUSED BY THE GOVERNMENT. THE REPAIR SHALL MATCH THE ADJACENT CONCRETE COLOR AND HAVE A 1 YEAR WARRANTY. MG028 ADD EXTERNAL NOTIFICATION HORNS PROVIDE EXTERNAL NOTIFICATION HORNS IN ACCORDANCE WITH THE ATTACHED SKETCHES, MG028 SHEET 1 - 3 OF 3. MG029 REVISE STORM INLET&400 HZ CABLE ITEM A.REVISE STORM INLET AND DRILL HOLES IN OTHER STORM INLETS IN ACCORDANCE WITH THE RESPONSE TO RFI #147. ITEM B.PROVIDE AND INSTALL 400 HZ CABLE IN ACCORDANCE WITH THE RESPONSE TO RFI #141.
© Copyright 2019
The Collier Report published by 1918 Media LLC.
Information displayed in this dossier has been provided through available open source or public sources.
No reliance should be made by readers or Collier Report subscribers.
Funding actions are complicated and do not always represent dollar-for-dollar payments to vendors nor do they represent payments in certain instances.
Requests for the modification of displayed information may be made to help.desk@1918.media.